Industrial prefabrication of building components significantly reduces construction costs. In the Netherlands, 70 percent of components in modular construction systems are already prefabricated. In Germany, this figure is currently only a third, but the trend is clearly rising.
A critical aspect of prefabricated construction is the concrete columns that support the entire building. In conventional construction, these are cast entirely on-site. When prefabricated columns are stacked, they must be connected in such a way that they possess sufficient load-bearing capacity.
In their diploma thesis at the Department Civil Engineering at the Giessen-Friedberg University of Applied Sciences, Almudena Miranda Chaparro and Magdalena Dietz empirically investigated the load-bearing behavior of prefabricated columns.
In an initial series of tests, the two aspiring civil engineers examined the effects of varying joint thicknesses and mortar strengths on the load-bearing behavior at the GiessenLaboratory for Structural Engineering. For this purpose, they cast a total of 42 concrete cubes. Two of these test specimens were then joined using different grouts. The aim of the experiments was to determine the influence of mortar strength and joint thickness on the deformation behavior of the test specimens. The components were therefore subjected to varying pressures using a press. The measurements revealed a loss of load-bearing capacity with increasing joint thickness for mortars with low strength. For mortars with a strength exceeding that of the concrete, joint thickness had no influence on the fracture behavior. No increase in load-bearing capacity was observed with further increases in mortar strength.
For Prof. Dr. Jens Minnert, who supervised the project together with Prof. Dr. Gerd Günther, the work by Chaparro and Dietz fills a research gap. For the first time, the series of experiments provides reference measurements for mortar selection depending on the optimal joint thickness. This allows for reliable work in construction practice. In many cases, this significantly simplifies the acceptance testing by structural engineers.
In a second series of experiments, the two graduate students investigated connections between steel-reinforced precast columns, which are created using bolts via column shoes and anchor bolts. They experimented with steel plates installed horizontally in the columns, which distribute pressure more effectively and increase the load-bearing capacity. The aim here was to reduce the number of column shoes required and thus make construction more cost-effective. According to Minnert, this series of tests revealed a promising approach to optimizing precast column connections.